83
3
83
5400/16CB
Alarm Panel, 16 Zones,
C-Bus Enabled
C-Bus
®
Enabled Security Panel
• On-board, direct connection to C-Bus
®
(no C-bus PC
Interface required)
• Supports the C-Bus
®
Security Application command set
• Alarm events such as Armed, Disarmed and Alarm can
be used to initiate C-Bus
®
commands, e.g turn C-Bus
®
controlled lighting on or off
• Ability to map up to 16 alarm events to 16 C-Bus
®
commands
• Ability to arm the security from C-Bus
®
input device (e.g,
touch screen or wall switch)
• Provided complete with a wall mounted security keypad
and rechargeable system backup battery
• Built in telephone dialer
• Access control features with provision for up to three
Wiegand card readers (Wiegand interface, readers and
cards purchased separately)
• 16 fully programmable security zones
• 16 physical security zone inputs with zone split option
• Two additional 24 hour inputs
• Plug-in RF interface to support a range of Wireless
detectors
• 4 programmable auxiliary outputs
• 56 user codes which can be assigned 3 to 6 digit PIN
codes
• Two button arming feature
• Programmable two area partitioning with overlapping of
zones in areas allowed
• Single or double trigger option on a zone-by-zone basis
• Supports up to 55 radio keys
• Secure DTMF remote arm / disarm capabilities
• Wide range of security and access control accessories are
available, including
o Expansion modules
o RF Expansion modules
o Sirens and Strobes
o Motion detectors
o RF motion detectors
o Reed switches
o Keypads
-Bus
Security Panel