2B. Basic Programming
1.0.4 Selecting Key Inputs
Once the loads have been selected, the user may choose one or more Input Units to control those
loads.
Select the Input switch(es) required to control the loads.
If you make a mistake simply press the key again to deselect it, and remove it from the current Learn
operation.
The simplest association is one involving a single switch and a single load. This would be achieved
by entering Learn Mode, pressing a Local Toggle button on an Output Unit (waiting to see that the
indicator lights), then pressing a key on an Input Unit and exiting Learn Mode.
1.1 Learn Mode Operations
C-Bus2 Learn Mode can be used to create a wide variety of exible control congurations. Basic On/
Off switches can be congured as well as Dimmer and Timer controls.
1.1.1 Relay and Dimmer Congurations
The type of control function assigned to the Input Units depends on whether you exit Learn Mode via
a Relay or Dimmer Output Unit. For a switching control function, exit on a Relay Unit. For a dimmer
function exit Learn Mode on a Dimmer Unit.
Key Function Exit Learn Mode Via:
Switching operation Relay Unit
Dimming operation Dimmer Unit
Other operations (eg Timer, PIR, etc) Relay OR Dimmer Unit
When the Output Unit used to exit Learn Mode is a relay then any keys included in a Learned
switching (relay) operation will become on/off switches: press once and the load comes on, press
again and the load goes off.
When the Output Unit used to exit Learn Mode is a dimmer then any keys selected for on/off
functions in that Learn session will have dimming capability as well. Pressing the key (Short Press)
toggles the light on or off. Pressing and holding the key down (Long Press) dims the light up or down
with a 4 second ramp rate.
1.1.2 Multi-way Control Congurations
One or more loads may be controlled from one or multiple locations by various input devices. The
example below allows for two-way switching or dimming controls to be configured.